Download the PHP package saffer-it/librenms-netconf without Composer

On this page you can find all versions of the php package saffer-it/librenms-netconf. It is possible to download/install these versions without Composer. Possible dependencies are resolved automatically.

FAQ

After the download, you have to make one include require_once('vendor/autoload.php');. After that you have to import the classes with use statements.

Example:
If you use only one package a project is not needed. But if you use more then one package, without a project it is not possible to import the classes with use statements.

In general, it is recommended to use always a project to download your libraries. In an application normally there is more than one library needed.
Some PHP packages are not free to download and because of that hosted in private repositories. In this case some credentials are needed to access such packages. Please use the auth.json textarea to insert credentials, if a package is coming from a private repository. You can look here for more information.

  • Some hosting areas are not accessible by a terminal or SSH. Then it is not possible to use Composer.
  • To use Composer is sometimes complicated. Especially for beginners.
  • Composer needs much resources. Sometimes they are not available on a simple webspace.
  • If you are using private repositories you don't need to share your credentials. You can set up everything on our site and then you provide a simple download link to your team member.
  • Simplify your Composer build process. Use our own command line tool to download the vendor folder as binary. This makes your build process faster and you don't need to expose your credentials for private repositories.
Please rate this library. Is it a good library?

Informations about the package librenms-netconf

librenms-netconf

CI Packagist

LibreNMS plugin that collects operational data from Junos devices over SSH — either as show … | display xml on a plain SSH session or through the NETCONF subsystem — and maps the values onto native LibreNMS objects (sensors, per-port metrics, custom metrics) using YAML definitions. Built for things SNMP cannot deliver on Junos, first of all EVPN-VXLAN state (duplicate MACs, ESI status, MAC/route counts).

Status: 1.4.1 on Packagist (lnms plugin:add saffer-it/librenms-netconf). Transports, credentials and the settings page, the YAML definition engine and the netconf poller/discovery module are verified against an EX4650 (Junos 23.4R2); the LDP, RPKI and VRRP definitions against recorded replies of a Junos 22.2 MPLS router. Extracted values are stored as native LibreNMS sensors (health tab, graphs, alert rules), per-port metrics and custom metrics with their own RRDs and graphs. The web UI has a NETCONF status page, a NETCONF tab on the device page (status, metrics, ESI-LAGs and, for admins, credentials with test connection and discover/poll now), a device overview panel, the EVPN fabric pages with topology map and MAC search, a fabric tracer (a MAC or IP to the full path through the fabric, with the interface on every hop), a port tab with the per-port counters and a "run a show command" form. Not in this version: license expiry (see CHANGELOG.md).

Requirements

Installation

route:cache is not optional on a production install: LibreNMS caches its routes in composer install (artisan optimize), plugin:add does not refresh that cache, and until it is rebuilt the plugin's pages and menu entry are missing. lnms plugin:enable netconf rebuilds it too, and daily.sh clears it on the next update. Since 1.2.1 the plugin notices the state, hides its own UI and writes a notification instead of breaking the page; older versions took the whole web UI down, because the plugin menu entry is rendered from LibreNMS's own menu on every page. artisan cache:clear does not help here — that is the application cache.

view:clear matters for the same reason on every install and upgrade: Composer extracts the package with the archive's timestamps, which can be older than compiled Blade views LibreNMS cached earlier, and Laravel then keeps the compiled copy (it recompiles only when the source is newer). The symptom is pages from the previous version — new code, old screens.

The plugin is enabled automatically. Open Overview → Plugins → Plugin Admin → netconf to set the global defaults (transport, port, username, password or SSH key). The poll budget there is a scheduling budget: the collector checks it between commands and stops issuing new ones once it is spent, so a run takes the budget plus the command in flight, extraction and storage; it does not abort a command.

Then run the migrations:

Enabling your first device

In the web UI: open the device, go to its NETCONF tab and press Enable NETCONF for this device, then Test connection and Discover now. The tab is offered on every device a shipped definition matches (Junos today) as soon as you are an admin, so this is the path for a single device. Credentials for that one device (if it differs from the global settings) are on the tab's Edit section.

For a fleet, the NETCONF status page (Plugins menu) enables every device of a device group and/or os at once, and Enable for all devices on the settings page turns it on globally.

The same from the command line:

--disable opts a device out again. The module also appears in the device's Modules tab.

Web UI

Graphs are rendered from the plugin's RRDs by /plugin/netconf/graph/... using the same size, font and colour parameters as core graphs (SVG or PNG per the webui.graph_type setting); counters are shown as rates per second.

Viewing needs access to the device (global-read for the status page); changing anything or talking to a device needs the admin role.

Device login class (Junos)

The plugin only runs show commands. A dedicated read-only class keeps the monitoring account from doing anything else. Verified 2026-09-21 on an EX4650 (Junos 23.4R2-S7.4): the single permission view is enough for every shipped definition (22 commands over cli/22 and netconf/830, password and SSH-key login), and show cli authorization parses for it.

Notes from the verification:

For the NETCONF subsystem (taken by the default auto transport when present, required by netconf) enable the service; it also speeds polling up considerably, see Transports:

The subsystem (on port 830 and on the SSH port) is authorised with the same permission flags as the CLI; no allow-commands entry for xml-mode or netconf is needed (verified on 23.4R2, the class above logs in and answers show version and <command> RPCs). set system services netconf rfc-compliant changes reply formatting but the server still advertises only base:1.0 (end-of-message framing) on 23.4R2; chunked framing (base:1.1) is implemented and unit-tested, but has not been seen live.

Transports

Mode How Default port
auto (default) one SSH login, then the netconf subsystem is requested on that connection; when the server refuses it (no set system services netconf ssh) the same connection continues with exec channels as cli. No second login or timeout; the status page shows which mode was negotiated 22
cli one SSH connection, each command runs as show … \| display xml on its own exec channel — the approach of junos_exporter 22
netconf NETCONF subsystem, hello/capability exchange, RFC 6242 end-of-message or chunked framing, <command format="xml"> for CLI strings and raw <rpc> bodies 830

All three return the same XML body. Junos offers the NETCONF subsystem on the SSH port as soon as netconf ssh is configured, so auto needs nothing but port 22. Prefer the subsystem where you can: a full preview of the shipped definitions on an EX4650 took 13 s over NETCONF and 45 s over exec with the recommended deny-commands class (19 s without it), because every exec channel starts a fresh CLI and pays the login-class evaluation again. netconf:test prints transport: netconf (auto) or cli (auto) plus the refusal reason. Pick cli explicitly for a device whose NETCONF service must stay off, netconf to use port 830 (a separate netconf service ACL, for example).

Host keys

By default the server host key is not verified (any key is accepted, as phpseclib does). For production set Host key check (known_hosts) on the settings page to an OpenSSH known_hosts file readable by the poller user, for example /opt/librenms/.ssh/known_hosts. Every device must then have an entry, otherwise the connection is refused with the fingerprint and the line to add:

Hashed entries, [host]:port entries for non-default ports, wildcards and @revoked markers are understood; a key that differs from every stored key for the host is reported as a host key mismatch and the device goes into back-off like any other connection failure.

Distributed pollers

The module runs inside the poller worker, so with distributed_poller every node that may poll a NETCONF device needs the node-local files the settings point at — the settings themselves live in the database and are shared, the paths in them are not:

Setting Must exist on every poller node
Private key file (key_file, or the per-device netconf_keyfile attribute) the key itself, same path, readable by the poller user
Host key check (known_hosts) the known_hosts file with an entry for every device — a node without it refuses the connection as a host key mismatch
Definitions directory (definitions_dir) the user definitions; a node that cannot see them polls with the shipped set only, silently

Two more shared-state points:

RRD needs nothing special: sensors and metrics go through LibreNMS's Datastore, so rrdcached applies exactly as it does for core modules. netconf:uninstall --purge is the exception — it deletes only RRD files it can see locally and lists the rest for removal on the rrdcached host.

Credentials

Global defaults live on the plugin settings page. Per device they can be overridden on the device page (/plugin/netconf/device/<id>) or with lnms netconf:device; the overrides are device attributes (netconf_username, netconf_password, netconf_keyfile, netconf_key_passphrase, netconf_port, netconf_transport). Secrets are encrypted with the LibreNMS APP_KEY and stored with a crypt: prefix; neither form shows them again.

The plugin only needs show commands. Run the monitoring account in the read-only login class above rather than super-user: lnms netconf:test warns when the account has configuration rights.

Commands

device accepts a hostname, IP, sysName or device_id; unknown hosts are tried with the global settings.

Definitions

Definitions are YAML files in resources/definitions/<vendor>/. A user directory (setting User definitions directory, default storage/app/netconf-definitions/) is loaded afterwards and overrides shipped files with the same name.

Shipped (Junos):

Definition Commands Produces
junos-evpn show evpn instance extensive, show evpn database state duplicate, show evpn l3-context count sensors for duplicate MACs (per instance + total, limit: 0), local ESIs without remote PE, degraded bridge domains, L3 contexts; state sensors for ESI resolution, ESI-LAG status, EVPN interface and IRB status; metrics per instance (local/remote MACs, neighbours, ESIs), per neighbour (route counts by type) and per ESI-LAG (DF, remote PEs)
junos-evpn-esi show mac-vrf forwarding vxlan-tunnel-end-point esi metrics per ESI-LAG (remote VTEPs, remote MACs) and per ESI-LAG/remote VTEP pair
junos-routing show route summary, show bgp summary count sensors for active and hidden routes per table, BGP peers configured/down (limit: 0); metrics per table, per table/protocol, per BGP RIB, per peer (flaps, messages, uptime, state) and per peer/RIB
junos-l2 show ethernet-switching table summary MAC table size and static entries (L2NG and pre-ELS shapes)
junos-interfaces show interfaces extensive per-port counters matched by snmp-index = ifIndex: CRC in/out, oversized, jabber, fragments, code violations, pause frames, framing errors, runts, MTU errors, carrier transitions, FEC corrected/uncorrected words and rates, PCS errored seconds, BPDU-block state
junos-interface-queues show interfaces extensive per port/queue queued, transmitted and dropped packets; off unless the Per-queue counters setting or the device attribute netconf_queues turns it on
junos-srx-cluster show chassis cluster status state sensors per redundancy group and node (primary/secondary/…), monitor failures, failover counters; only on hardware matching /srx/i
junos-alarms show system alarms, show chassis alarms major/minor alarm counts (limit: 0 for major)
junos-ntp show ntp status, show ntp associations state sensor synchronised/unsynchronised, stratum (limit: 15), reachable peers (limit_low: 1); metrics for offset, root delay/dispersion, jitter, frequency and per peer
junos-system show system uptime, show system commit, show krt queue KRT queue length (warn_limit: 100); metrics for uptime, seconds since last commit, last commit epoch/user/client, load averages, per KRT queue
junos-license show system license usage features in use without a valid license (warn_limit: 0); metrics per feature
junos-lacp show lacp interfaces state sensor per LAG member (mux state), count of members not distributing per LAG (limit: 0)
junos-ldp show ldp neighbor, show ldp session neighbour count, sessions not operational (limit: 0), state sensor per session
junos-rpki show validation session, show validation statistics state sensor per cache session, sessions not up (limit: 0), invalid origin count; metrics per session (flaps, prefixes) and the validation statistics
junos-vrrp show vrrp summary state sensor per interface/group (master, backup, init), groups neither master nor backup (limit: 0)
junos-evpn-fabric show evpn instance extensive, show mac-vrf forwarding vxlan-tunnel-end-point source / remote / esi / remote mac-table (every 3rd poll), show interfaces vtep rows for the EVPN fabric tables (netconf_evpn_neighbor, _esi, _vni, _vni_vtep, _tunnel); only with the EVPN fabric view setting
junos-evpn-fabric-mac show evpn database (every 3rd poll) netconf_evpn_mac: the EVPN MAC database with active source (ESI / remote VTEP / local IFL) and IPs; on by default with the EVPN fabric view setting, switchable globally (EVPN MAC database) and per device (attribute netconf_evpn_mac)

Commands whose subsystem is not running ("LDP instance is not running", "vrrp subsystem not running") are recognised and skipped without creating sensors, so every definition can be shipped enabled. Only commands every Junos device answers are required in the shipped definitions (show system uptime, show system alarms, show chassis alarms, show route summary, show interfaces extensive); a required command the device does not answer fails the run like a lost connection: the status row records it, the device backs off and the first failure lands in the eventlog. The same command in several definitions runs once with the merged settings — required if any use is required, as often as the most frequent use — and lnms netconf:validate prints a hint when definitions disagree. The LDP, RPKI and VRRP definitions were verified against recorded replies of a Junos 22.2 MPLS router (anonymised copies in tests/fixtures/junos/); the other definitions live on an EX4650.

Alert rules for the sensors and for the JSON columns of netconf_metrics are in Alerting below.

Schema

Table columns are coerced to the column type (int, string, ip, mac as 12 hex digits, bool from XPath booleans or Up/Down/Yes/No texts, json from a node-set or a space separated text, datetime); a value that does not fit is stored as null with a warning. Rows are merged on the key, so several mappings (and commands) may fill different columns of the same row; rows that vanish from a reply are deleted per device once every mapping of that table delivered data.

filter: keeps big replies small: Junos accepts an interface pattern before or after the options (show interfaces extensive xe-0/0/*, show interfaces et-0/0/[0-3] extensive), so a user definition can copy junos-interfaces with filter: 'et-*' and the 1 MB reply of a 48-port leaf shrinks to the uplinks. The filter is part of the command identity: two definitions with different filters run the command twice. Fixtures for --replay are named after the filtered command.

Namespaces are stripped before evaluation, so paths never need prefixes; attributes keep their local name (elapsed-time/@seconds). Prefer string(...) over number(...) for values that may carry a sign or a unit (+0.325, 1,234 bps): XPath's number() turns those into NaN, while the plugin parses strings itself. Rows inside multi-routing-engine-results (Virtual Chassis) are matched by // expressions like any other and expose {re}.

What lands where

Definition section LibreNMS object Storage Alerting
sensors native sensors with poller_type = netconf, sensor_type = netconf-<definition>-<id>; state sensors get state translations sensors table, rrd/<host>/sensor-<class>-netconf-…rrd, any other configured datastore standard sensor alert rules (sensors.sensor_current > sensors.sensor_limit, state generic value); eventlog on threshold crossing and state change
ports rows matched to the ports table by ifIndex (or ifName/ifDescr/ifAlias) netconf_port_metrics (last values as JSON), rrd/<host>/netconf-port-<port_id>-<definition>-<mapping>.rrd, one data source per field Advanced-SQL alert rules on netconf_port_metrics.values
metrics free-form rows netconf_metrics (last values + labels as JSON), rrd/<host>/netconf-<definition>-<mapping>-<index>.rrd Advanced-SQL alert rules on netconf_metrics.values
tables rows of the EVPN fabric tables, typed columns, merged on the key across mappings, pruned per device netconf_evpn_<table> (neighbor, esi, vni, vni_vtep, tunnel, mac); no RRD. The fabric resolver derives netconf_evpn_{vtep,fabric,fabric_member,underlay_link} from them, the checks netconf_evpn_issue{,_device} and the EVPN fabric critical issues sensor, and, with ESI peers as neighbours, rows in the core links table (protocol = evpn-esi) Advanced-SQL alert rules on the netconf_evpn_* tables (only with the EVPN fabric view setting)

Per device, netconf_device_status keeps the transport, matched definitions, poll count, last success, last error and the back-off: after a failed session the device is skipped for 1, 2, 4, … polls (capped by Back-off maximum), with one eventlog entry on the first failure and one on recovery. lnms netconf:device <device> shows this row.

Notes:

EVPN fabric view (preview)

Enable EVPN fabric view on the settings page to collect the per-leaf EVPN tables (junos-evpn-fabric, four extra commands per leaf) and to aggregate them across devices: every VTEP or EVPN peer address becomes a node, resolved to a LibreNMS device where one owns the address; EVPN neighbours, ESI peers, VXLAN tunnels, EVPN BGP sessions and confirmed underlay links (shared point-to-point subnet with a BGP, OSPF or IS-IS session, LLDP as confirmation) connect the nodes, and every connected component is one fabric (netconf_evpn_fabric, key = lowest VTEP address, members in netconf_evpn_fabric_member). Roles: leaf (terminates VXLAN), gateway (anycast IRBs), spine (EVPN session only), plus a border flag for L3 contexts. VTEPs that are not monitored devices are kept as "unknown" members. A member row with pinned = 1 keeps its fabric and role on recompute.

The MAC database (netconf_evpn_mac, ~5 000 rows and 1.3 MB per busy leaf, read every third poll) is collected on every fabric device by default. Switch it off for the whole install with EVPN MAC database on the settings page, and decide per device on the device's NETCONF tab (Edit → EVPN MAC database: global default, enabled, disabled) or from the command line:

The device attribute always wins over the setting, and nothing is collected while the EVPN fabric view setting is off. The per-queue counters (netconf_queues) work the same way, with the global default the other way round: off unless asked for.

EVPN multihoming peers as neighbours

Every ESI-LAG of a leaf identifies its multihoming peer: the ESI is the same on both leaves and the remote PE addresses name the peer's VTEP. The fabric resolver turns that into

Caveat: core's discovery-protocols module deletes every links row of a device that its own LLDP/CDP run did not produce. The plugin's discovery module runs after it (last in discovery_modules) and writes the rows again in the same run, so they are only ever missing for the seconds in between and their id changes on every discovery.

Fabric pages

With the fabric view on, the Plugins menu gains EVPN fabrics (/plugin/netconf/fabrics): one row per fabric with members by role, instances, VNIs, ESIs, MACs and health badges. Each fabric has tabs:

Tab Content
Overview the eagle view (below), the health badges, the totals and, for admins, the fabric's name and notes
Members device, VTEP / router-id, role, platform, location, instances, VNIs, ESI-LAGs (DF count), MACs, neighbours, tunnels, collector state; unknown VTEPs with their BGP description
BGP overlay per member and peer: state and uptime (core bgpPeers with the evpn SAFI, or the plugin's show bgp summary rows), flaps, bgp.evpn.0 prefix counts, EVPN route counts by type from show evpn instance extensive; a peer that other members have and one lacks is listed as missing
VNIs per VNI: VLAN tag per leaf (mismatch flagged), carriers, flood list with gaps and stale entries between monitored carriers, orphans, anycast IRBs, remote MACs; filter and issues-only switch
ESI / multihoming per Ethernet segment: every PE (monitored sides with LAG and resolution state, remote-only PEs), mode, DF/BDF, aliasing, LACP members not distributing, remote MACs; flags for single PE, DF disagreement, mode mismatch, LAG down, unresolved, aliasing off
Tunnels per member: vtep.N per remote VTEP with mode, next-hop, and — once core has discovered the IFL as a port — traffic, errors and a graph; reverse-tunnel check where the far end is monitored
MACs the MAC search scoped to the fabric
Trace source and destination to the full path through the fabric (below)
Checks the open issues of the consistency checks (below) with severity, message, involved devices, first and last seen; filter by severity, check and text; legend of every check

The eagle view

The overview draws the whole fabric as one server-rendered SVG: role-coloured cards wrapped inside site compounds (the device's location, inherited by ESI partners, else the ESI-pair cluster), stacked in tiers. A compound holds up to four cards per row with one or two sites and two per row beyond that, and the compounds pack into rows no wider than 1,120 px, so 26 members are two rows rather than a 3,780 px strip. Pan and zoom move a viewBox; the camera is remembered per fabric in the browser, and reset forgets it.

Above the picture, one sentence names the shape and says what it was concluded from:

On the cards: SNMP down, not monitored, monitored but without EVPN data, a degraded-ESI count, and a version that is not the fabric's majority. Between them, underlay links coloured and dashed by state (up solid, down dashed, no session state dotted, WAN its own pattern, cross-site solid in its own colour), and orange ESI-LAG brackets — anycast gateway segments on an irb unit are not ESI-LAGs and are not drawn as one.

The toolbar collapses sites (a collapsed compound keeps its label and takes the worst state of what it hides), turns on the sessions out of the fabric (a border router's transit and IX peers, off by default), and turns on the devices attached to the ESI-LAGs, from core's own discovery rows. Clicking a card, a link or an ESI opens an inspector under the picture instead of leaving the page, and the selection is in the URL. An ESI panel carries the traffic of that LAG: one summed graph over the aggregated interface of every PE plus one per PE, and no graph image is requested until a panel is opened.

The previous pictures are still there for one release: ?topo=interactive is the vis-network map, ?topo=static the one-row SVG.

Tracer

The Trace tab and lnms netconf:trace answer "how does this address reach that one":

Each endpoint is looked up in the EVPN MAC database, then in core's bridge tables, then in core ARP, and the answer names every source with what it returned — including the empty ones, and including whether MAC collection is off on the devices in scope. A leaf that only learnt the MAC from the fabric is corroboration, not an attachment.

The path is every minimum-hop path through the stored underlay (parallel links stay separate; no routing protocol's edge is preferred). Trace live (admin only) instead asks each device on the way what its own forwarding table says, which is the only thing that knows the answer where several equal paths exist; it opens one SSH session per device, at most twelve per trace, closes them on every path, falls back to the stored graph where it cannot reach, and writes nothing.

Under the one-liner: a hop table with both interfaces, the protocol, the session state and a traffic graph per hop, and a "what was checked" list — the same VNI on both ends, a tunnel each way, the VNI in both flood lists, the EVPN session listed by both sides, the DF and aliasing of a multihomed attachment, and whether either MAC is suppressed or has been moving. A question that cannot be answered reads unknown, never no. A trace between two VNIs stops and names the gateways that have an IRB in both; routed traces are not implemented.

MAC search (/plugin/netconf/evpn/mac?q=, also linked from the fabric list): a MAC in any notation (or a prefix), an IP or a VNI. Results are every opted-in leaf's view from the EVPN database — local port, ESI with its PEs and their LAGs, or remote VTEP resolved to the device — next to the core FDB and ARP rows for the same MAC or IP.

Everything on these pages is read from the netconf_evpn_* tables and core tables; nothing talks to a device. Only sessions, flood lists and ESIs of monitored members are known, so gaps can only be judged between monitored leaves.

Fabric checks

At the end of every resolve (each poll of a member leaf) the plugin runs a set of consistency checks over the fabric and keeps the findings in netconf_evpn_issue (the devices each one involves in netconf_evpn_issue_device). An issue keeps its first_seen while it persists; last_seen is the last resolve that still found it. Severities are critical, warning and info.

Check Severity Raised when
neighbor-asymmetric warning a member lists another monitored member as EVPN neighbour, the other does not list it back
session-down critical an overlay BGP session of a member towards another member is not established (state from core bgpPeers or show bgp summary)
session-missing warning a member lacks a session to a peer that the other monitored members have
vni-flood-gap critical a leaf advertises a VNI — it is in some member's flood list for it — but is missing from another carrier's flood list. Carrying a VNI is not the condition: a VLAN template instantiates a VNI on every leaf and a leaf announces it only where the bridge domain has an up interface. A VNI with only two carriers cannot be judged, because the witness would have to be the flood list that is missing the entry
vni-stale-flood warning a flood list points at a member the plugin collects from that does not carry the VNI
vni-orphan warning a VNI on a leaf has no remote VTEP at all while another member does advertise it
vni-vlan-mismatch info the same VNI maps to different VLAN tags on different leaves (legal)
vni-irb-down critical the anycast IRB of a VNI is not up on a gateway
vni-irb-partial info some carriers of a VNI have an IRB, others do not (legal for a gateway pair)
esi-single-pe critical an Ethernet segment with a local ESI-LAG has no peer PE (warning when the segment is only known from one remote PE)
esi-df-disagree critical the PEs name different designated forwarders, or more than one monitored side claims the DF role
esi-mode-differs critical all-active on one PE, single-active on the other
esi-lag-down critical the ESI-LAG is not up on a PE
esi-unresolved critical the ESI is not resolved on a PE
esi-lacp-degraded warning LACP members of the ESI-LAG are not distributing (junos-lacp)
esi-no-aliasing warning aliasing is disabled on one PE of a segment
dup-mac critical MACs are suppressed by duplicate-MAC detection on a leaf (the dup-mac-instance sensor)
dup-mac-params warning threshold, window or recovery time of duplicate-MAC detection differ between leaves of one instance
mac-mobility warning a MAC in the MAC database changed its active source more than MAC mobility limit times within one hour (moves, moves_recent, moves_since on netconf_evpn_mac). Off by default — MAC mobility limit ships at 0; the check has never met a production fabric's MAC data, so look at the MACs tab first and then pick a number
route-count warning a member receives no MAC routes from a neighbour that has local MACs in the same instance
version-skew info the monitored members run different software versions
unknown-vtep warning a member address does not belong to a monitored device
tunnel-asymmetric warning a member has a VXLAN tunnel to another member that has none back
tunnel-errors warning the vtep.N port of a tunnel counted errors or discards in the last poll
member-not-polling warning the NETCONF collection of a member is failing, so its data may be stale
member-not-collected warning a member is a device in LibreNMS but the plugin has no EVPN data from it (not enabled, or polled and silent). It is left out of every comparison instead of being blamed for the others' asymmetries — enable NETCONF on it to complete the fabric view

Alerting hooks, in the order you will probably use them:

lnms netconf:fabric --checks prints the open issues on the command line.

Alerting

Sensors work with the normal rule builder; the metric tables need Override SQL on the Advanced tab of the rule (the statement goes into Query, ? is replaced by the device id, any returned row raises the alert). The builder rules below are written the way the rule list shows them. sensors.sensor_alert = 1 keeps the per-sensor alert toggle of the health tab working; drop it if you do not use that toggle.

Duplicate MACs (count sensor). One alert per EVPN instance that reports duplicate MACs; the sensor already carries limit: 0, so the generic Sensor over limit rule from the collection fires too. Use netconf-junos-evpn-dup-mac-total instead for one alert per device.

Template line: {{ $value['sensor_descr'] }}: {{ $value['sensor_current'] }} duplicate MACs inside the @foreach ($alert->faults as $key => $value) loop.

EVPN fabric issues (count sensor). One alert per fabric member with critical issues involving it (the Checks tab of the fabric lists all severities):

Fabric checks by check or severity (Override SQL on netconf_evpn_issue). The issue table is fabric-level; join netconf_evpn_issue_device to alert on the devices involved (the rule then fires per device), or leave the device out for one alert per fabric on any device that runs the plugin:

ESI-LAG down (state sensor). The state_sensor_critical macro joins the state translations, so the rule fires on the state the definition marks generic: 2 (Down) and stays quiet on Unknown:

Replace the first condition with sensors.sensor_type LIKE "netconf-%" (operator begins with) for one rule that covers every critical netconf state: ESI unresolved, EVPN interface or IRB down, LACP member not distributing, LDP session, RPKI cache, VRRP group, SRX node. The template gets {{ $value['state_descr'] }} from the join.

BGP peer flapped (Override SQL on netconf_metrics). flaps is a counter and the table holds only the last value, so SQL cannot compute an increase; the direct signal is uptime, the seconds since the session came up. A peer that has flapped at least once and whose session is younger than 15 minutes:

The alert clears by itself once the session is 15 minutes old; the flap history is on the peer's graph on the metrics page. values needs the backticks (reserved word); numeric fields are stored as numbers, labels as strings (JSON_UNQUOTE).

More one-liners of the same kind:

Rows in netconf_metrics keep the values of the last successful poll, so a device in back-off alerts through the last rule rather than through stale metric rows.

Upgrade and uninstall

Upgrade. daily.sh re-installs every plugin listed in composer.plugins.json at the version constraint plugin:add recorded (^1.0 for a 1.x install), so patch and minor releases arrive with the regular LibreNMS update. To move on purpose, or to a specific version, run plugin:add again, then the migrations:

Read the Upgrade notes of the release in CHANGELOG.md first; nothing has to be deleted for an upgrade, the RRDs heal themselves (see What lands where).

Disable. ./lnms plugin:disable netconf stops polling and discovery, hides the pages and the commands and keeps all data; plugin:enable netconf resumes.

Uninstall. ./lnms plugin:remove saffer-it/librenms-netconf only removes the package. Everything the plugin stored stays behind:

What Where
sensors with poller_type = netconf (values, state translations) sensors table, rrd/<host>/sensor-<class>-netconf-*.rrd
custom and per-port metrics tables netconf_metrics, netconf_port_metrics, files rrd/<host>/netconf-*.rrd
per-device status and back-off table netconf_device_status
per-device switches and credential overrides devices_attribs rows netconf_enabled, netconf_evpn_mac, netconf_queues, netconf_username, …
module scheduling config keys poller_modules.netconf, discovery_modules.netconf
the plugin's migrations rows in the migrations table
global settings including the encrypted password row netconf in the plugins table (LibreNMS deletes it itself once the package is gone)

netconf:uninstall removes all of that in an order a concurrently running poller cannot undo (plugin disabled and module keys erased first, rows and files next, tables and migration rows last). It stays available while the plugin is disabled:

Alert rules that reference the plugin's sensors or tables are listed by the command and left for you to delete (rules on netconf_metrics fail once the table is gone). Also untouched: the SSH key and known_hosts files and the user definitions directory. To start over rather than uninstall, run --purge, then plugin:enable netconf, migrate and enable the devices again.

Development

composer.lock is committed and resolved for PHP 8.2 (config.platform.php), so every CI job and every checkout installs the same dependency set; run composer update on purpose only. LibreNMS resolves the plugin against its own lock file, so the platform pin has no effect on installations.

Unit tests need no LibreNMS installation: the transports are exercised against a scripted NETCONF server (tests/Support/NetconfServerScript.php) and recorded, anonymised Junos replies in tests/fixtures/junos/.

To try the plugin in a local LibreNMS checkout add a path repository to its composer.json and run ./lnms plugin:add saffer-it/librenms-netconf:

License

MIT


All versions of librenms-netconf with dependencies

PHP Build Version
Package Version
Requires php Version ^8.2
ext-dom Version *
ext-libxml Version *
ext-openssl Version *
librenms/plugin-interfaces Version ^1.0
phpseclib/phpseclib Version ^3.0
symfony/yaml Version ^6.4 || ^7.0
Composer command for our command line client (download client) This client runs in each environment. You don't need a specific PHP version etc. The first 20 API calls are free. Standard composer command

The package saffer-it/librenms-netconf contains the following files